WhatsApp

×

İletişim Bilgileri

Site içi arama

Carbo 47

SPECIAL FEATURES: Calculates C-level from the residual oxygen content of gas or CO2-content from the furnace atmosphere Converts the L-probe voltage to the voltage curve of a zirconium oxide ... Devamı

Takip Edin:

Açıklama

SPECIAL FEATURES:

  • Calculates C-level from the residual oxygen content of gas or CO2-content from the furnace atmosphere
  • Converts the L-probe voltage to the voltage curve of a zirconium oxide probe
  • Parameter input via plug-in terminal
  • Menu-guided operation
  • High operation per galvanic separation of all inputs
  • Optional connection of two thermocouples Type “K” and “S”
  • Additional input for CO-analyzer

INTELLIGENT TRANSMITTER TYPE: CARBO 47

INTELLIGENT TRANSMITTER TYPE: CARBO 47

 

SPECIAL FEATURES:

  • Calculates C-level from the residual oxygen content of gas or CO2-content from the furnace atmosphere
  • Converts the L-probe voltage to the voltage curve of a zirconium oxide probe
  • Parameter input via plug-in terminal
  • Menu-guided operation
  • High operation per galvanic separation of all inputs
  • Optional connection of two thermocouples Type “K” and “S”
  • Additional input for CO-analyzer
INTELLIGENT TRANSMITTER TYPE: CARBO 47
 

FUNCTION

The Carbo 47 is an intelligent transmitter designed for connecting different types of sensors. The unit processes the input signals and outputs the desired output variable as a voltage or current unit signal.

The versions described here convert the residual oxygen content of the gas to other components such as C-level based on the assumed gas equilibrium.

Determination of the C-level in conjunction with a conventional controller enables a favorably priced system for controlling carbon atmospheres in heat treatment plants.

The system still contains the facilities offered by more expensive systems, such as actual value correction (see below). The investment is soon amortized even on smaller furnace systems.

Another practical function of the unit is the conversion of the L-probe voltage into the probe voltage of a conventional zirconium oxide probe (see the appropriate datasheet for the L-probe). This allows the cheaper, more robust L-probe to be adapted to existing control systems.

 

TECHNICAL DATA

 

Housing: Wall housing made of polystyrene
Dimensions: 296 x 256 x 118 mm (WxHxD)
Weight: approx. 2 kg
Protection type: IP 50 according to DIN 40050
Climate: • Storage: -10…+70 °C
• Operation: 0…+50 °C
• 5…95 % relative humidity, non-condening
Auxiliary voltage: 115 / 230 Vac +- 10 % 50 – 60 Hz
Power consumption: approx. 15 VA
Fuse: 230V:1x 0,315 A slow blow

 

Analogeingänge: Type 1:
– thermocouple, Type “K” or “S”
– L-probe
Type 2:
– thermocouple, Type “K” or “S”
– L-probe – CO-analyzer
Type 3:
– thermocouple, Type “K” or “S”
– ZrO2-probe – CO-analyzer
Type 4 :
– thermocouple, Type “K” or “S”
– CO2-analyzer 0…3 % log. or 0…0.5 % lin.

 

 

İndirelibilir Dosyalar

30 yılı aşkın tecrübemiz ile sektöre olan hizmetlerimiz artarak devam etmektedir.

  • +90 232 348 73 10

  • +90 545 936 9151

  • bilgi@simteknik.com.tr

  • S.İ.M. Teknik Isıl İşlem Makinaları Elektrik Elektronik ith. İhr. San. Tic. Ltd. Şti. Egemenlik, 6106. Sk. No:89, 35070 Bornova/İzmir

  • Hafta İçi: 09:00 - 17:00
    Cumartesi: Kapalı