Nitromat-M

SPECIAL FEATURES: Menu-guided operation Foil keyboard Exact control Connections of two thermocouples by choice Input for MESA H2-measuring system Program memory with ... Devamı

Takip Edin:

Açıklama

SPECIAL FEATURES:

  • Menu-guided operation
  • Foil keyboard
  • Exact control
  • Connections of two thermocouples by choice
  • Input for MESA H2-measuring system
  • Program memory with 99 setpoint- programs for H2- and process temperature (time-synchronous)
  • Program tracks, free eligible
  • Position-proportional control
  • ON/Off-PID-control
  • Transfer outputs
  • Options:
    · Setpoint generator for process temperature
    · Serial interfaces (RS422/RS485)
 

CONTROL SYSTEM TYPE: NITROMAT-M

 

FUNCTION

The Nitromat-M is a single-channel measuring and control system for furnace atmosphere- control in Nitriding- or Nitrocarburizing processes.

By switch settings on the backside of the instrument, Nitromat-M can be easily adapted to different sensor connections.

 The program controls of temperature and hydrogen, with program tracks for NH3 – N2 – Endogas – CO2, etc. eligible, is a propitious possibility for control Nitriding- or Nitrocarburizing atmospheres in furnaces.

 

TECHNICAL DATA

 

Construction: The type of protection of the front is IP 43
Dimensions: 144 x 144 x 300 mm (WxHxD)
Auxiliary voltage: 115 or 230 Vac ± 10%; 50/60 Hz
Power consumption: About 15 VA
Analog Input:
  • H2 Analyzer
  • Thermocouple, type K or S
  • Terminal temperature (Pt 100)
  • External set value: analog or through a serial interface
Digital Input:
  • IN0: program release with setpoint program in progress: otherwise, controller locked
  • IN1: program continuation in succession
  • IN2: input disable
Switching outputs:
  • 5 control tracks freely available
  • 2 switching outputs for 1 motor valve for gas or solenoid valves for ammonia and H2
  • Signal actual values intolerance range
  • Signal program active
  • Signal Alarm indication (all outputs “open collector” 24 V / 100 mA)
Measuring range: 0,2…80 %
Analogausgänge:
  • selected, 0 to 20 mA, 4 to 20mA or 0 to 10 Vdc
  • for the H2 -Value
Display: Graphical LCD display with 160 x 128 pixels
Operation: Five keys (soft keys) with user guidance (menu guidance);
the respective function of the keys indicated on the display
Setpoint:
  • 4 preset points for C level
  • 99 setpoint programs for H2-profiles, internally storable and recallable; (programtraveltimeperprogram:upto100h)
  • 23segments/program
  • External entry by means of program generator, for example, 0…20 mA, 4…20 mA, 0…10 V.
Serial interface (option): RS232
RS 422/RS 485
Climate:
  • Storage: -10…+60 °C
  • Operation: 0…+50 °C
  • 5…95 %relative humidity, non-condensing

 

 

 

 

 

 

İndirelibilir Dosyalar

Teknik Döküman

İncele / İndir

30 yılı aşkın tecrübemiz ile sektöre olan hizmetlerimiz artarak devam etmektedir.

  • +90 232 348 73 10

  • +90 545 936 9151

  • bilgi@simteknik.com.tr

  • S.İ.M. Teknik Isıl İşlem Makinaları Elektrik Elektronik ith. İhr. San. Tic. Ltd. Şti. Egemenlik, 6106. Sk. No:89, 35070 Bornova/İzmir

  • Hafta İçi: 09:00 - 17:00
    Cumartesi: Kapalı
    Pazar: Kapalı